Rơ le bảo vệ 7UM6225-4EB91-0BA0+L0S
Mã hiệu | Thông số kỹ thuật |
Rơ le 7UM6221-5EB92-0HA0 L0S | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL,DOUBLE, LC-CONNECTOR (FROM OCT. 09) SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: TRANSFORMER WITHOUT ADDITIONAL FUNCTIONS |
Rơ le 7UM6221-6EB02-0CB0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 220V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR FULL ADDITIONAL FUNCTION: SENSITIVE ROTOR EARTH FAULT PROTECTION AND 100%-STATOR EARTH FAULT PROTECTION |
Rơ le 7UM6225-2BC91-0BA0 L0R | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT SURFACE MOUNTING CASE, TERMINALS ON THE TOP AND BOTTOM CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 17V LANGUAGE AMERICAN, 60HZ, ANSI, REGION US, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG SERVICE INTERFACE (PORT C) DIGSI/MODEM ELECTRICAL RS232 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR STANDARD WITHOUT ADDITIONAL FUNCTIONS |
Rơ le 7UM6225-5EB22-0AA0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, ELECTRIC RS 485 SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR BASIS WITHOUT ADDITIONAL FUNCTIONS |
Rơ le 7UM6225-5EB91-0AA0 L0E | “MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″”, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, 820NM FIBER, ST-PLUG SERVICE INTERFACE (PORT C) DIGSI/MODEM ELECTRICAL RS232 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR BASIS WITHOUT ADDITIONAL FUNCTIONS” |
Rơ le 7UM6225-5EB91-3CG0 L0A | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, ELECTR.RS485 SERVICE INTERFACE (PORT C) DIGSI/MODEM ELECTRICAL RS232 METERING: PEAK VALUES, MIN/MAX-VALUES, ENERGY METERING FUNCTIONALITY: GENERATOR FULL ALL ADDITONAL FUNCTIONS |
Rơ le 7UM6225-5EB92-3AA0 L0D | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, ELECTRIC RS485 SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 METERING: PEAK VALUES, MIN/MAX-VALUES, ENERGY METERING FUNCTIONALITY: GENERATOR BASIS WITHOUT ADDITIONAL FUNCTIONS |
Rơ le 7UM6225-5EB92-3FA0 L0A | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19″, 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, ELECTR.RS485 SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 METERING: PEAK VALUES, MIN/MAX-VALUES, ENERGY METERING FUNCTIONALITY: ASYNCHRONOUS MOTOR WITHOUT ADDITIONAL FUNCTIONS |
Vũ Đình –
đã gửi yêu cầu báo giá Siemens 7UM6225-2BC91-0BA0 L0R kiểm tra báo giá trong email sớm giúp tôi